Digital Linear and Passive Components sources an exhaustive range of semiconductors, including: Hall sensors, Power Management Switching Regulators, Linear & Shunt Regulators and ICT PLD's, USB Power Switch & Reset IC's, Amplifiers, Diodes & Rectifiers, Transistors,Fets & Mosfets, Zener TV's & Protection, Temperature Sensors, and Low On-Resistance Analog Multiplexers and Switches & Universal Transducer Interfaces(UDI's).

Among others, we source all the big brands including Recom, Luminary Micro, Mornsun, Zywyn, and Assemtech / Comus.

Tilt/Tip (Tilt Switches-Glass)


 

TILT AND TIP-OVER SWITCHES
The tilt and tip-over switches and motion sensors are available as mercury metal and our patented non-mercury metal (patents #5.209.343 and #5.332.876.). Mercury glass tilt switches are also available. All switches are evacuated, filled with inert gas and hermetically sealed to ensure long life and low contact resistance.

TILT SWITCHES

Tilt switches are used to sense movement (tilt) of a device above and below a horizontal axis. A typical use is in a thermostat. A glass mercury switch is mounted to a bi-metallic spring which expands and contracts with temperature. As the spring moves, the switch contacts pass through the horizontal plane, opening or closing to operate the furnace or boiler. The angle through which the switch must move for proper operation – the differential angle – is measured from the point of just make to just break; it is specified as a maximum. When selecting a tilt switch, it is important to ensure that the operating mechanism can move the switch through an angle greater than the differential angle. Some additional applications include: level controls, appliances, security alarm systems, toys and games, float switches and water-treatment equipment (non-mercury) .

TIP -OVER SWITCHES

Tip-over switches sense tilt over 360° of a vertical axis. A common use is in portable heaters used in the home to prevent electrical shock or fire. When the heater tilts more than a specified angle, the switch operates turning the heater off. This angle, called the operating angle, describes the angle from vertical to the point of contact operation, subject to a tolerance, ie. 45° ± 10° (35° to 55°). Both normally closed (tilt to open) and normally open (tilt to close) switches are available. Some additional applications include: portable lamps, PC anti-theft devices, vending-machine alarms and machinery security systems

Tilt switch:Ball contact
Tilt switch: Opto
Tilt switch: Micro miniature
Tilt switch: Non mercury contacts
Tilt switch: Surface mount
Tip over switch: Ball contact
Electronic Tilt sensor

Serial
Number
Details
Product
PDF
CF52-0
Switching Voltage: 240 Vac
Switching Current: 13.0A
Differential Angle: 9.5°±3.5°Max.
Contact Resistance: 0.050 Ohms
Glass L: 1.375in (34.93mm)
H: 1.5in (38.1mm)
Contact: Form C (SPDT)
Heavy Duty
CK30-0
Contact Resistance: 0.3 Ohms
Switching Voltage: 240 Vac
Switching Current: 5.0A
Differential Angle: 30° +/- 2° Deg Max
Glass L: 57.0mm (2.24in)
Dia: 22.4mm (.882in)
Contact: Form A Normally Open
Wide Angle
Download PDF
CA20-SO
Switching Voltage: 240 Vac
Switching Current: 0.05A
Differential Angle: 10° Max
Contact Resistance: 0.1 Ohms Max
Glass Max. Length: .550in (13.97mm)
Glass Dia: .165in (4.19mm)
Contact: Form "A" (SPST)- Normally Open
Sub-Miniature
Download PDF
CA22-SO
Switching Voltage: 240 Vac
Switching Current: 0.05A
Differential Angle: 5° Max
Contact Resistance: 0.1 Ohms Max
Glass Max. Length: .88in (22.35mm)
Glass Dia: .175in (4.45mm)
Contact: Form "A" (SPST)- Normally Open
Standard
Download PDF
CA22-1-SO
Switching Voltage: 240 Vac
Switching Current: 0.05A
Differential Angle: 1° Max
Contact Resistance: 0.1 Ohms Max
Glass Max. Length: .88in (22.35mm)
Glass Dia: .175in (4.45mm)
Contact: Form "A" (SPST)- Normally Open
Precision 1°
Download PDF
CH02-SO
Switching Voltage: 240 Vac
Switching Current: 0.1A
Differential Angle: 0.5° Max
Contact Resistance: 0.1 Ohms Max
Glass Max. Length: 1.950in (49.53mm)
Glass Dia: .35in (8.89mm)
Contact: Form "A" (SPST)- Normally Open
Low Angle
Download PDF
CH03-SO
Switching Voltage: 120 Vac
Switching Current: 0.2A
Differential Angle: 1.4° Max
Contact Resistance: 0.1 Ohms Max
Glass Max. Length: 1.375in (34.92mm)
Glass Dia: 0.35in (8.89mm)
Contact: Form "A" (SPST)- Normally Open
Thermostat Switch
Download PDF
CB11-SO
Switching Voltage: 120 Vac
Switching Current: 1.0A
Differential Angle: 5.0° Max
Contact Resistance: 0.030 Ohms Max
Glass Max. Length: 1.375in (34.92mm)
Glass Dia: 0.35in (8.89mm)
Contact: Form "A" (SPST)- Normally Open
Wetted Contact
Download PDF
CB17-SO
Switching Voltage: 240 Vac
Switching Current: 2.0A
Differential Angle: 10.0° Max
Contact Resistance: 0.050 Ohms Max
Glass Max. Length: 1.375in (34.92mm)
Glass Dia: 0.35in (8.89mm)
Contact: Form "A" (SPST)- Normally Open
General Purpose
Download PDF
CK12-SO
Switching Voltage: 240 Vac
Switching Current: 1.0A
Differential Angle: 30.0°±5.0° Max
Contact Resistance: 0.050 Ohms Max
Glass Max. Length: 1.19in (30.23mm)
Glass Dia: 0.325in (8.26mm)
Contact: Form "A" (SPST)- Normally Open
Pump Application
Download PDF
CH04-SO
Switching Voltage: 240 Vac
Switching Current: 0.1A
Differential Angle: 2.0° Max
Contact Resistance: 0.1 mOhm Max.
Glass Max. Length: 1.625in (41.275mm)
Glass Dia: 0.350in (8.98mm)
Contact: Form "C" (SPDT)- Normally Open
Wetted Contact
Download PDF
CL34-SO
Switching Voltage: 240 Vac
Switching Current: 2.0A
Differential Angle: 10.0° Max
Contact Resistance: 1.0 Ohms Max
Glass Max. Length: 2.0in (50.8mm)
Glass Dia: 0.495in (12.57mm)
Contact: Form "A" (SPST)- Normally Open


Download PDF
CL62-SO
Switching Voltage: 240 Vac
Switching Current: 5.0A
Differential Angle: 3.0° Max
Contact Resistance: -
Glass Max. Length: 2.625in (66.675mm)
Glass Dia: 0.600in (15.24mm)
Contact: Form "A" (SPST)- Normally Open
Download PDF
CL64-SO
Switching Voltage: 240 Vac
Switching Current: 5.0A
Differential Angle: 5.0° Max
Contact Resistance: -
Glass Max. Length: 2.25in (57.15mm)
Glass Dia: 0.600in (15.24mm)
Contact: Form "A" (SPST)- Normally Open
Download PDF
CB18-SO
Switching Voltage: 240 Vac
Switching Current: 2.0A
Differential Angle: 10.0° Max
Contact Resistance: 0.1 Ohms Max
Glass Max. Length: 1.50in (38.10mm)
Glass Dia: 0.350in (8.89mm)
Contact: Form "A" (SPST)- Normally Open
General Purpose - 2 Electrodes
 
Download PDF